# Access control door schedule

Build the door schedule an access control job starts from, and see the equipment and cable it adds up to.

Name or location

Door type

Lock

Reader

Cable run from controller

m

Reader on the way out as well (otherwise an exit button)

Quantities

Doors

1

Door controllers

1

Two doors each

Readers

1

Power supplies

1

12 V 5 A, one per four doors

Exit buttons

1

Break-glass units

1

For magnetic and glass locks

Door contacts

1

Card or tag reader1

Magnetic lock (fail-safe)1

Cable, with 10% spare

Reader cable (6-core)33 m

Lock cable (2-core)33 m

Exit button cable (2-core)33 m

Door contact cable (2-core)33 m

Doors on escape routes must release when the fire alarm sounds and open freely from inside. The fire officer's rules and the lock data sheet decide the final design.

Method

## How the numbers are worked out

### Per door

Each door has a type, a lock, a reader and an exit device. Double doors count two locks and two readers; turnstiles and barriers use their built-in lock.

### Counts

Controllers are two-door units. One 12 V 5 A power supply serves about four doors. Magnetic and glass locks each need a break-glass release. Cable is the run from the controller times the cores each device needs, plus 10% spare.

### Assumptions and limits

-   Doors on escape routes must release on a fire alarm and open freely from inside; fire rules decide the lock choice.
-   Cable lengths are runs from the controller. Add cabling to the network switch if controllers are networked.
-   Final selection follows the data sheets of the reader, lock and controller chosen.

### Related

-   [Access control and building systems](https://kinnex.in/solutions/access-control-building-systems/)
-   [Fire detection estimate](https://kinnex.in/tools/fire-detection-estimate/)

Nothing you type here leaves your device unless you choose to send it to us. These are planning estimates; a survey or the equipment data sheet confirms the final figures.

## Want an engineer to check it?

Send us what you worked out and we will come back with a design based on the real site.

[Book an assessment](https://kinnex.in/assessment/)[Call KINNEX](tel:+918618131661)[WhatsApp](https://wa.me/918618131661?text=Hi%20KINNEX%2C%20I'd%20like%20to%20know%20more%20about%20your%20IT%20and%20security%20services.)