Planning tool
Cabling and PoE planner
Upload a floor plan (PDF, DXF, DWG or image), set its scale, and place every outlet, access point, camera and comms rack. The planner works out each cable run, the cable to order, the switches and the PoE load for each rack.
Method
How the planner works out the cabling
Cable runs
Each outlet goes to its nearest comms rack (or the one you choose). The run is the distance along the plan's x and y directions, the way cable follows walls and trays, plus the drop from the ceiling tray to the outlet, the rise at the rack, and the slack you set for each end.
Racks
For each rack: outlets, ports with spare, switches of the size you choose, the PoE load of its devices plus 10%, the longest run, and the total cable.
Limits to watch
- A copper permanent link is at most 90 m. Runs over it are drawn in red and listed.
- PoE draws are typical values per device type. Use the data sheets, and thePoE budget calculator for cameras with infrared and PTZ.
Then
Turn the totals into an order with thebill of quantities builder, and check the rack with the rack elevation planner.